PaperPanorama

Nuclear Experiment·nucl-ex

Mon·Jul 25, 2016

2 papers0 primary·2 cross-listed·reconstructed*

  1. 01*

    The quest to find an electric dipole moment of the neutron

    P. Schmidt-Wellenburg🇨🇭

    Until now no electric dipole moment of the neutron (nEDM) has been observed. Why it is so vanishingly small, escaping detection for the last 65 years, is not easy to explain. In general it is considered as one of the most sensitive probes for the violation of the combined symmetry of charge and parity (CP). A discovery could shed light on the poorly understood matter/antimatter asymmetry of the Universe. The neutron EDM might one day help to distinguish different sources of CP-violation in combination with measurements of paramagnetic molecules, diamagnetic atoms and other nuclei. This review presents an overview of the most important concepts in searches for an nEDM as well as a brief overview of the worldwide efforts.

    hep-exnucl-exphysics.ins-det17 citations
  2. 02*

    Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

    G. Boissonnat (LPCC) · J.-M. Fontbonne (LPCC) · E. Balanzat (CIMAP) · F. Boumard (LPCC) · B. Carniol (LPCC) · A. Cassimi (CIMAP) · J. Colin (LPCC) · D. Cussol (LPCC) · D. Etasse (LPCC) · C. Fontbonne (LPCC) · A.-M. Frelin (GANIL) · J. Hommet (LPCC) · J. Peronnel (LPCC) · S. Salvador (LPCC)

    Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.

    physics.med-phnucl-exNucl.Instrum.Meth.A(2017)·1 citation

* Reconstructed cohort: no mailing for this day survives in the archive. Papers are grouped by their submission times and arXiv's announcement cut-off, assuming announcement without delay; positions follow identifier order. Validated at ~91% exact-day agreement against the archived era.